國家衛生研究院 NHRI:Item 3990099045/4857
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 12145/12927 (94%)
造訪人次 : 855283      線上人數 : 1038
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於NHRI管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4857


    題名: Development of 1.5D cylindrical HIFU phased array
    其他題名: 2008 IEEE International Ultrasonics Symposium
    作者: Chen, GS;Chang, H;Liu, R;Shung, KK
    貢獻者: Division of Medical Engineering Research
    摘要: High intensity focused ultrasound, HIFU has been used to non-invasively treat human tumors, such as uterine fibroids, prostate cancer, breast cancer, liver tumor, and brain tumor. However, the tumor in some organs can be moved by human breathing and heart beat, which may cause the ablation and damage of normal tissues during the sonication of HIFU. The purpose of this study was to develop a HIFU phased array for tracking the moving tumors. In the initial design, the array had a center frequency of 1.0 MHz and 512 elements that allowed symmetric control. PZT-4 1-3 composites were formed via the ldquodice and fillrdquo technology and then shaped into a cylindrical structure. The results simulated by Field II demonstrated that the array in water had a dynamic focusing range from 145 mm to 175 mm in Depth and a steering range from -15 mm to 15 mm in azimuthal direction with respect to the center of the array. A prototype of the array was fabricated. The aperture of the array was 15 cm by 12 cm and the radius of curvature was 15 cm. The impedance of each channel (a pair of elements) was measured and the average was 1500 Ohm. Surface acoustic intensity up to 12.6 W/cm2 was applied to one piece of cylindrical PZT4-composite consisting of 22 elements for 50 minutes, and the temperature of the composite was not observed to rise appreciably. A 256-channel amplifier was utilized to drive the array without impedance matching in water and the water spring was observed at the natural focus of the array when the driving signal to each channel was zero-phase at 0.9 MHz. The phase control and impedance matching circuits for each channel are being designed.
    日期: 2008-11
    關聯: Ultrasonics Symposium. 2008 Nov:792-794(Article number 4803563).
    Link to: http://dx.doi.org/10.1109/ULTSYM.2008.0190
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000268845800190
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=67649307168
    顯示於類別:[陳景欣] 會議論文/會議摘要
    [張恕(2004-2017)] 會議論文/會議摘要

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    SCP67649307168.pdf2935KbAdobe PDF699檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋