國家衛生研究院 NHRI:Item 3990099045/4857
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 851185      在线人数 : 557
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4857


    题名: Development of 1.5D cylindrical HIFU phased array
    其它题名: 2008 IEEE International Ultrasonics Symposium
    作者: Chen, GS;Chang, H;Liu, R;Shung, KK
    贡献者: Division of Medical Engineering Research
    摘要: High intensity focused ultrasound, HIFU has been used to non-invasively treat human tumors, such as uterine fibroids, prostate cancer, breast cancer, liver tumor, and brain tumor. However, the tumor in some organs can be moved by human breathing and heart beat, which may cause the ablation and damage of normal tissues during the sonication of HIFU. The purpose of this study was to develop a HIFU phased array for tracking the moving tumors. In the initial design, the array had a center frequency of 1.0 MHz and 512 elements that allowed symmetric control. PZT-4 1-3 composites were formed via the ldquodice and fillrdquo technology and then shaped into a cylindrical structure. The results simulated by Field II demonstrated that the array in water had a dynamic focusing range from 145 mm to 175 mm in Depth and a steering range from -15 mm to 15 mm in azimuthal direction with respect to the center of the array. A prototype of the array was fabricated. The aperture of the array was 15 cm by 12 cm and the radius of curvature was 15 cm. The impedance of each channel (a pair of elements) was measured and the average was 1500 Ohm. Surface acoustic intensity up to 12.6 W/cm2 was applied to one piece of cylindrical PZT4-composite consisting of 22 elements for 50 minutes, and the temperature of the composite was not observed to rise appreciably. A 256-channel amplifier was utilized to drive the array without impedance matching in water and the water spring was observed at the natural focus of the array when the driving signal to each channel was zero-phase at 0.9 MHz. The phase control and impedance matching circuits for each channel are being designed.
    日期: 2008-11
    關聯: Ultrasonics Symposium. 2008 Nov:792-794(Article number 4803563).
    Link to: http://dx.doi.org/10.1109/ULTSYM.2008.0190
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000268845800190
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=67649307168
    显示于类别:[陳景欣] 會議論文/會議摘要
    [張恕(2004-2017)] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP67649307168.pdf2935KbAdobe PDF699检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈