國家衛生研究院 NHRI:Item 3990099045/4507
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 858544      在线人数 : 568
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4507


    题名: Potential usage of liposome-encapsulated phosphor for in vivo imaging of tissue oxygenation
    作者: Lo, L;Ho, J;Chang, Y;Chang, C;Yang, C
    贡献者: Division of Medical Engineering Research
    摘要: Oxygen-dependent quenching of phosphorescence can provide a quantitative measurement with high temporal resolution of tissue oxygenation in vivo. It is a real-time optical means for prognosis of diseases where the oxygen concentration is essential. Phosphorescence quenching is a non-invasive methodology, otherwise no more than minimally invasive as the phosphor is necessarily introduced into vasculature prior to the measurement. Oxyphor R2, a dendritic phosphor with two-layer of glutamates, is a suitable phosphor for oxygen measurements owing to its high water solubility. We used a frequency-domain, phase modulation based instrument to calibrate Oxyphor R2. The acquired quenching constant (k<sub>Q</sub>) and lifetime at zero oxygen (τ°) were consistent with those calibrated from conventional time-domain instrument. Administered with Oxyphor R2, the rat hepatic oxygen distributions were imaged throughout the course of ischemia and reperfusion. After 5 min ischemia and subsequent 20 min reperfusion, distinct ischemic areas on the hepatic tissue were observed. In order to extend the application of in vivo oxygen imaging using phosphorescence quenching by minimizing the possible immunoresponse induced by phosphor, we are the first to co-synthesize the dipalmitoylphosphatidylglycerol (DPPG)-rich liposome with Oxyphor R2 to generate the liposome-encapsulated Oxyphor R2. Its calibration using the frequency domain measurement displayed higher quenching constant and shorter lifetime at zero oxygen (k<sub>Q</sub> = 1186 mmHg<sup>-1</sup> sec<sup>-1</sup>; τ° = 150 μsec) comparing to original Oxyphor R2 (k<sub>Q</sub> = 438 mmHg <sup>-1</sup> sec<sup>-1</sup>; τ° = 630 μsec). It implicated that the liposome-encapsulated Oxyphor R2 designed to neutralize the immunoresponse could be further applied to measure the tissue oxygenation in vivo, especially those with low oxygen concentration such as tumor.
    日期: 2004-08
    關聯: Biomedical Engineering - Applications, Basis and Communications. 2004 Aug;16(4):224-232.
    Link to: http://www.worldscinet.com/bme/16/1604/S10162372041604.html
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=8644235831
    显示于类别:[羅履維] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP8644235831.pdf1420KbAdobe PDF330检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈