國家衛生研究院 NHRI:Item 3990099045/15012
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 855155      在线人数 : 992
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/15012


    题名: Accuracy of point-of-care blood glucometers in neonates and critically Ill adults
    作者: Sheen, YJ;Wang, JM;Tsai, PF;Lee, WJ;Hsu, YC;Wang, CY;Sheu, WH
    贡献者: Institute of Molecular and Genomic Medicine
    摘要: PURPOSE: Inpatient glycemic management has become a common issue because of the increasing number of hospitalized patients with hyperglycemia. Point-of-care devices can enable timely inpatient glucose monitoring, which may lead to better outcomes. The accuracy of point-of-care testing in various clinical scenarios has been questioned, particularly in neonates and critically ill patients. This study aimed to evaluate the accuracy of the CONTOUR PLUS and CONTOUR PLUS ONE glucometers (new wireless systems that link to a smart mobile device) when used as point-of-care devices for blood glucose monitoring in neonates and critically ill adults in inpatient settings. METHODS: This cross-sectional study was conducted at a medical center in central Taiwan and enrolled patients admitted to the neonatal intensive care unit, sick child room, or respiratory intensive care unit between November 2020 and April 2021. Neonates with suspected infection or abnormal blood coagulation and adults who had abnormal blood coagulation, were pregnant, had received organ transplants, or had undergone massive blood transfusions were excluded. The accuracy of the glucometers was determined based on the following criteria of the International Organization for Standardization (ISO) standard: 15197:2013. FINDINGS: Overall, 114 neonates (mean age, 4.2 days [range, 0-28 days]; 65 boys [57.0%]) and 106 hospitalized critically ill adults (mean age, 68.2 years [range, 27-94 years]; 72 men [67.9%]) were enrolled in this study. The glucose values obtained with each glucometer had good precision, and all findings met the reference criteria of the within-lot results. All measurements of the neonates' venous blood by each glucometer met the accuracy criteria specified by ISO standard 15197:2013. Furthermore, 98.1% and 97.2% of the arterial blood glucose measurements for critically ill adults obtained with CONTOUR PLUS and CONTOUR PLUS ONE met the accuracy criteria, respectively. IMPLICATIONS: Both glucose management systems met the accuracy criteria for venous blood from neonates and arterial blood from critically ill adults. Thus, the use of these 2 point-of-care devices in inpatient settings, including for neonates and critically ill adults, can be recommended to minimize limitations associated with the clinical application of point-of-care testing in glucose management. The wireless connection may play a role in the subsequent development of institution-wide virtual glycemic management under the supervision of a team of endocrinologists.
    日期: 2023-07
    關聯: Clinical Therapeutics. 2023 Jul;45(7):643-648.
    Link to: http://dx.doi.org/10.1016/j.clinthera.2023.05.005
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0149-2918&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:001067014000001
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85160331390
    显示于类别:[許惠恒] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    PUB37248091.pdf687KbAdobe PDF104检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈