國家衛生研究院 NHRI:Item 3990099045/6379
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 853233      在线人数 : 737
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/6379


    题名: An efficient voxel-driven system model for helical pinhole SPECT
    作者: Huang, PC;Hsu, CH;Hsiao, IT;Lin, KM
    贡献者: Division of Medical Engineering Research
    摘要: Conventionally, a pinhole SPECT acquires data by rotating the Gamma-camera in a circular orbit. However, such a acquisition method could merely scan a very limited field­of-view (FOV). For a longer object, it requires several circular acquisitions over various bed positions to cover the entire object. Multiple-bed acquisition also requires a high accurate movement control to avoid the overlapping or gap between any adjacent bed positions. In this work, we propose a voxel-driven (VO) system model (projection matrix) for iterative helical pinhole SPECT image reconstruction. The photon detection along helical trajectory can reduce acquisition time without multiple-bed over­lapping and gap problems. However, the most challenging part for helical pinhole SPECT is the increase in image volume. For efficient computation and matrix storage reduction, the geometric symmetries derived from helical trajectory shall be fully utilized. By using a 16-fold symmetry derived from helical trajectory, the system matrix requires only 90 degrees information of projection geometry. A multi-threaded code can be implemented to accelerate the projection computation. The result for a two line sources phantom study shows that the VO model is efficient and suitable for iterative helical pinhole SPECT. The VO matrix could model the helical trajectory pinhole SPECT efficiently and handle a longer object without increasing any storage space of system matrix. The proposed model is also ready to be extended multiple-pinhole system for to better sensitivity as well as other fast reconstruction algorithms.
    日期: 2011-10
    關聯: Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2011 IEEE. 2011 Oct:4158-4161.
    Link to: http://dx.doi.org/10.1109/NSSMIC.2011.6153795
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000304755604082
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=84858649218
    显示于类别:[林名釗] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP84858649218.pdf742KbAdobe PDF665检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈