國家衛生研究院 NHRI:Item 3990099045/5636
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12189/12972 (94%)
造访人次 : 955292      在线人数 : 656
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/5636


    题名: New ray-driven system matrix for small-animal pinhole-SPECT with detector blur, geometric response and edge penetration modeling
    其它题名: IEEE Nuclear Science Symposium Conference Record
    作者: Wietholt, C;Hsiao, IT;Chen, CT;Ieee
    贡献者: Division of Medical Engineering Research
    摘要: Iterative reconstruction of pinhole SPECT projection data acquired in preclinical animal imaging research benefits from modeling physical parameters of the imaging process. In this study, we developed a ray-driven system model that accounts for detector blur, the geometric response and edge penetration of the pinhole. GATE 2.2.0/GEANT 4 Monte Carlo simulations utilizing a tungsten knife-edge pinhole with an aperture diameter of 2 mm were applied to measure the pinhole point spread function (PSF) and to generate pinhole SPECT projection images of 2 different resolution phantoms (2.0 mm and 1.8 mm). The new Monte Carlo based PSF with edge penetration was compared to an ideal pinhole model without edge penetration. To conserve memory, the ray-driven system matrix was computed for one angle and rotation was performed by interpolating the radiotracer distribution within the object space. Detector symmetry and a bitwise incremental storage scheme were utilized for further reduction of memory requirements. Two system setups with a magnification of 7.2x and 2x were studied. Reconstruction results show an improvement in image quality and reconstruction resolution for the new pinhole PSF model. In the low magnification system operated at its resolution limits these improvements are more pronounced than in the high magnification system. The newly implemented ray-driven reconstruction method has great flexibility and offers to be a platform for further improvements such as non-uniform attenuation and scatter correction, and integration of detector misalignments in the system matrix.
    日期: 2006-10
    關聯: Nuclear Science Symposium Conference Record, 2006. IEEE. 2006 Oct:3414-3419.
    Link to: http://dx.doi.org/10.1109/NSSMIC.2006.353735
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000288875603105
    显示于类别:[其他] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    ISI000288875603105.pdf201KbAdobe PDF444检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈