國家衛生研究院 NHRI:Item 3990099045/4855
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 908747      在线人数 : 1020
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/4855


    题名: Focused ultrasound thermal therapy system with ultrasound image guidance and temperature measurement feedback
    其它题名: 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS'08
    作者: Lin, KH;Young, SY;Hsu, MC;Chan, H;Chen, YY;Lin, WL
    贡献者: Division of Medical Engineering Research
    摘要: In this study, we developed a focused ultrasound (FUS) thermal therapy system with ultrasound image guidance and thermocouple temperature measurement feedback. Hydraulic position devices and computer-controlled servo motors were used to move the FUS transducer to the desired location with the measurement of actual movement by linear scale. The entire system integrated automatic position devices, FUS transducer, power amplifier, ultrasound image system, and thermocouple temperature measurement into a graphical user interface. For the treatment procedure, a thermocouple was implanted into a targeted treatment region in a tissue-mimicking phantom under ultrasound image guidance, and then the acoustic interference pattern formed by image ultrasound beam and low-power FUS beam was employed as image guidance to move the FUS transducer to have its focal zone coincident with the thermocouple tip. The thermocouple temperature rise was used to determine the sonication duration for a suitable thermal lesion as a high power was turned on and ultrasound image was used to capture the thermal lesion formation. For a multiple lesion formation, the FUS transducer was moved under the acoustic interference guidance to a new location and then it sonicated with the same power level and duration. This system was evaluated and the results showed that it could perform two-dimensional motion control to do a two-dimensional thermal therapy with a small localization error 0.5 mm. Through the user interface, the FUS transducer could be moved to heat the target region with the guidance of ultrasound image and acoustic interference pattern. The preliminary phantom experimental results demonstrated that the system could achieve the desired treatment plan satisfactorily.
    日期: 2008-08
    關聯: IEEE Engineering in Medicine and Biology Society Conference Proceedings. 2008 Aug:2522-2525(Article number 4649713).
    Link to: http://dx.doi.org/10.1109/IEMBS.2008.4649713
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000262404501233
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=61849097879
    显示于类别:[張恕(2004-2017)] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP61849097879.pdf736KbAdobe PDF939检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈