    题名: Split-focused ultrasound for breast tumor thermal surgery with multidirectional heating
    其它题名: 2007 IEEE Ultrasonics Symposium, IUS
    作者: Cheng, TY;Ju, KC;Ho, CS;Chen, YY;Lin, WL
    贡献者: Division of Medical Engineering Research
    摘要: This study investigated the feasibility of using split-focused ultrasound transducers with mechanical rotation to do multi-direction heating for breast tumor thermal therapy. The driving frequency, radius of curvature, and side length of the rectangle spherical transducer are 0.5 MHz, 10 cm, and 7 cm, respectively. In order to alleviate the rib heating, the transducer was tilted be 45 degree relative to the muscle/bone interface, and its focal zone was shifted with 6 mm away from the center of the planning target volume (PTV). Based on the multi-focus temporal switching technique, strategies employing single transducer and multiple transducers were both evaluated. As a single transducer was used, the transducer was rotated sequentially to achieve a uniform heating from four planned positions with 90 degree apart. While in multiple ultrasound transducers cases, an appropriate arrangement was designed to have the same configuration of acoustic beams in the single-transducer case. Computer simulations and in vitro phantom had been studied for this ultrasound heating system. The results demonstrated the capacity of this system design; it was able to effectively shorten the treatment time by generating a larger thermal lesion through multi-focus switching and sparing the cooling interval through multidirectional sonications. This study indicated that by appropriate arrangement of a single or multiple split-focused transducers with mechanical rotation, it is very promising to implement multi-direction heating for breast tumor thermal therapy.
    日期: 2007-10
    關聯: 2007 IEEE Ultrasonics Symposium, IUS. 2007 Oct:1776-1779.
    Link to: http://dx.doi.org/10.1109/ULTSYM.2007.447
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000254281801195
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=48149091731
    显示于类别:[其他] 會議論文/會議摘要

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP48149091731.pdf415KbAdobe PDF683检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈