    题名: Development and validation of an isotope-dilution electrospray ionization tandem mass spectrometry method with an on-line sample clean-up device for the quantitative analysis of the benzene exposure biomarker S-phenylmercapturic acid in human urine
    作者: Lin, LC;Tyan, YC;Shih, TS;Chang, YC;Liao, PC
    贡献者: Division of Environmental Health and Occupational Medicine
    摘要: An isotope-dilution electrospray ionization tandem mass spectrometry (ESI-MS/MS) method with an on-line sample clean-up device, for the quantitative analysis of human urine for the benzene exposure biomarker S-phenylmercapturic acid (SPMA), was developed and validated. The sample clean-up system was constructed from an autosampler, a reversed-phase C18 trap cartridge, a two-position switching valve, and controlling computer software and hardware. The sample clean-up system was interfaced via 1/20 splitting to the ESI source of a triple-quadrupole mass spectrometer using negative ion mode and multiple reaction monitoring for SPMA and the isotope-labeled internal standard. A strategy was adopted to acquire pooled blank urine matrix and quality control samples spiked with standards. Validated procedures and data on method specificity, detection limits, standard curves, precision and recovery, sample storage stability, and inter-laboratory comparison are presented. The analytical system was fully automated. No tedious manual sample clean-up procedures are required. With the selectivity and the sensitivity provided by ESI-MS/MS detection, the analytical system can be used for high-throughput and accurate determination of SPMA levels in human urine samples, as a biomarker for environmental as well as occupational benzene exposure.
    关键词: Chemistry, Analytical;Spectroscopy
    日期: 2004
    關聯: Rapid Communications in Mass Spectrometry. 2004;18(12):1310-1316.
    Link to: http://dx.doi.org/10.1002/rcm.1488
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0951-4198&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000222077100009
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=3042599194
    显示于类别:[張玉珍(2000-2003)] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    000222077100009.pdf336KbAdobe PDF1617检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈