Title: | Rapid creation of a temporary isolation ward for patients with severe acute respiratory syndrome in Taiwan |
Authors: | Fung, CP;Hsieh, TL;Tan, KH;Loh, CH;Wu, JS;Li, CC;Chang, FY;Siu, LK;Yen, MY;Wang, LS;Wong, WW;Kao, WF;Hsu, JH;Lin, TH;Huang, FY;Lee, CH |
Contributors: | Division of Clinical Research |
Abstract: | OBJECTIVES: To rapidly establish a temporary isolation ward to handle an unexpected sudden outbreak of severe acute respiratory syndrome (SARS) and to evaluate the implementation of exposure control measures by healthcare workers (HCWs) for SARS patients. DESIGN: Rapid creation of 60 relatively negative pressure isolation rooms for 196 suspected SARS patients transferred from 19 hospitals and daily temperature recordings of 180 volunteer HCWs from 6 medical centers. SETTING: A military hospital. RESULTS: Of the 196 patients, 34 (17.3%) met the World Health Organization criteria for probable SARS with positive results of serologic testing for SARS-associated coronavirus (SARS-CoV), reverse transcriptase polymerase chain reaction (RT-PCR) from nasopbaryngeal or throat swabs for SARS-CoV, or both. Seventy-four patients had suspected SARS based on unprotected exposure to SARS patients; three of them had positive results on RT-PCR but negative serologic results. The remaining 88 patients did not meet the criteria for a probable or suspected SARS diagnosis. Of the 34 patients with probable SARS, 13 were transferred to medical centers to receive mechanical ventilation due to rapid deterioration of chest x-ray results, and three patients died of SARS despite intensive therapy in medical centers. During the study period, one nurse developed probable SARS due to violation of infection control measures, but there was no evidence of cross-transmission to other HCWs. CONCLUSIONS: Despite the use of full personal protection equipment, the facility failed to totally prevent exposures of HCWs to SARS but minimized the risk of nosocomial transmission. Better training and improvements in infection control infrastructure may limit the impact of SARS. |
Keywords: | Public, Environmental & Occupational Health;Infectious Diseases |
Date: | 2004-12 |
Relation: | Infection Control and Hospital Epidemiology. 2004 Dec;25(12):1026-1032. |
Link to: | http://dx.doi.org/10.1086/502339 |
JIF/Ranking 2023: | http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0899-823X&DestApp=IC2JCR |
Cited Times(WOS): | https://www.webofscience.com/wos/woscc/full-record/WOS:000225725100005 |
Cited Times(Scopus): | http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=10844247165 |
Appears in Collections: | [蕭樑基] 期刊論文
|
Files in This Item: