國家衛生研究院 NHRI:Item 3990099045/15725
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 12145/12927 (94%)
造訪人次 : 857749      線上人數 : 794
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於NHRI管理 到手機版
    請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/15725


    題名: Dose-response relationship between lung function and chest imaging response to silica exposures in artificial stone manufacturing workers
    作者: Chen, CH;Tsai, PJ;Chang, WW;Chen, CY;Chen, CY;Yates, D;Guo, YL
    貢獻者: National Institute of Environmental Health Sciences
    摘要: Background: Occupational exposure to artificial stone, a popular material used for countertops, can cause accelerated silicosis, but the precise relationship between silica dose and disease development is unclear. Objectives: This study evaluated the impact of silica exposure on lung function and chest imaging in artificial stone manufacturing workers. Methods: Questionnaire and spirometry assessments were administered to workers in two plants. A high-exposure subset underwent further evaluation, including chest CT and DLco. Weighting factors, assigned as proxies for silica exposure, were based on work tasks. Individual cumulative exposures were estimated using area concentration measurements and time spent in specific areas. Exposure-response associations were analyzed using linear and logistic regression models. Results: Among 65 participants, the mean cumulative silica exposure was 3.61 mg/m(3)-year (range 0.0001 to 44.4). Each 1 mg/m(3)-year increase was associated with a 0.46% reduction in FVC, a 0.45% reduction in FEV1, and increased lung function abnormality risk (aOR = 1.27, 95% CI = 1.03-1.56). Weighting factors correlated with cumulative exposures (Spearman correlation = 0.59, p < 0.0001), and weighted tenure was associated with lung function abnormalities (aOR = 1.04, 95% CI = 1.01-1.09). Of 37 high-exposure workers, 19 underwent chest CT, with 12 (63%) showing abnormal opacities. Combining respiratory symptoms, lung function, and chest X-ray achieved 91.7% sensitivity and 75% specificity for predicting chest CT abnormalities. Conclusion: Lung function and chest CT abnormalities occur commonly in artificial stone workers. For high-exposure individuals, abnormalities on health screening could prompt further chest CT examination to facilitate early silicosis detection.
    日期: 2024-03-02
    關聯: Environmental Health. 2024 Mar 02;23:Article number 25.
    Link to: http://dx.doi.org/10.1186/s12940-024-01067-1
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1476-069X&DestApp=IC2JCR
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85186605922
    顯示於類別:[郭育良] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    ISI001179170200001.pdf1578KbAdobe PDF48檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋