English  |  正體中文  |  简体中文  |  Items with full text/Total items : 12145/12927 (94%)
Visitors : 849011      Online Users : 1504
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version
    Please use this identifier to cite or link to this item: http://ir.nhri.org.tw/handle/3990099045/1516


    Title: A new approach for pulse processing in positron emission tomography
    Authors: Xie, QG;Kao, CM;Hsiau, Z;Chen, CT
    Contributors: Division of Medical Engineering Research
    Abstract: In this paper, we propose a new technique for positron emission tomography (PET) pulse processing that has the potential to overcome design limitations in PET arising from the need to use fast, high-cost analog-to-digital converters (ADCs). In this technique, we consider the voltage pulse derived from the charge pulse generated by a scintillator/photomultiplier tube (PMT) detector upon a detection event and model the voltage pulse by a fast, linearly rising edge followed by a slower exponential decay. Based on this model, we show that the basic parameters of the voltage pulse that are relevant for PET event detection can be determined from a trigger time and four time intervals measured on the pulse. We also discuss an electronic implementation in which the required measurements can be obtained by using clocks, comparators, and registers, thereby eliminating the use of ADCs and constant fraction discriminators in PET front-end electronics. We conduct computer simulation studies to evaluate the performance of the proposed technique and our results are promising. When used with Cerium Doped Lutetium Oxyorthosilicate (LSO)/PMT, the proposed technique can generate accurate results for the photon energy, the event time, and the decay-time constant. In addition, it can support an energy resolution of about 30% and a coincidence window of about 10 ns. On the other hand, in its present form the proposed technique is not suitable for use with BGO/PMT due to its low light yield.
    Keywords: Engineering, Electrical & Electronic;Nuclear Science & Technology
    Date: 2005-08
    Relation: IEEE Transactions on Nuclear Science. 2005 Aug;52(4):988-995.
    Link to: http://dx.doi.org/10.1109/TNS.2005.852966
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0018-9499&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000231436700027
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=27644437977
    Appears in Collections:[蕭子凱(2001-2004)] 期刊論文

    Files in This Item:

    File Description SizeFormat
    000231436700027.pdf429KbAdobe PDF798View/Open


    All items in NHRI are protected by copyright, with all rights reserved.

    Related Items in TAIR

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback