國家衛生研究院 NHRI:Item 3990099045/14991
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 12145/12927 (94%)
造访人次 : 907083      在线人数 : 853
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于NHRI管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: http://ir.nhri.org.tw/handle/3990099045/14991


    题名: Simultaneous biomonitoring of volatile organic compounds’ metabolites in human urine samples using a novel in-syringe based fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis
    作者: Gurrani, S;Prakasham, K;Huang, PC;Wu, MT;Wu, CF;Lin, YC;Tsai, B;Krishnan, A;Tsai, PC;Ponnusamy, VK
    贡献者: National Institute of Environmental Health Sciences
    摘要: Assessing the impact of human exposure to environmental toxicants is often crucial to biomonitoring the exposed dose. In this work, we report a novel fast urinary metabolites extraction (FaUMEx) technique coupled with UHPLC-MS/MS analysis for the highly sensitive and simultaneous biomonitoring of the five major urinary metabolites (thiodiglycolic acid, s-phenylmercapturic acid, t,t-muconic acid, mandelic acid, and phenyl glyoxylic acid) of common volatile organic compounds' (VOCs) exposure (vinyl chloride, benzene, styrene, and ethylbenzene) in human. FaUMEx technique comprises of two-steps, liquid-liquid microextraction was performed first in an extraction syringe using 1 mL of methanol (pH 3) as an extraction solvent and then, the extractant was passed through a clean-up syringe (pre-packed-with various sorbents including 500 mg anhydrous MgSO4, 50 mg C18, and 50 mg SiO2) to obtain the high order of matrice clean-up and preconcentration efficiency. The developed method displayed excellent linearity, and the correlation coefficients were >0.998 for all the target metabolites with detection and quantification limits of 0.02–0.24 ng mL−1 and 0.05–0.72 ng mL−1, respectively. Furthermore, the matrix effects were < ±5%, and inter and intra-day precision were <9%. Moreover, the presented method was applied and validated to real sample analysis for biomonitoring of VOC's exposure levels. The results showed that the developed FaUMEx-UHPLC-MS/MS method is fast, simple, low-cost, low-solvent consumption, high sensitivity with good accuracy and precision for five targeted urinary VOCs' metabolites. Therefore, the presented dual-syringe mode FaUMEx strategy with UHPLC-MS/MS technique can be applied to biomonitoring of various urinary metabolites to assess human exposure to environmental toxicants.
    日期: 2023-07
    關聯: Chemosphere. 2023 Jul;329:Article number 138667.
    Link to: http://dx.doi.org/10.1016/j.chemosphere.2023.138667
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0045-6535&DestApp=IC2JCR
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85152523565
    显示于类别:[黃柏菁] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    SCP85152523565.pdf5330KbAdobe PDF146检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈