    題名: On the closing sounds of a mechanical heart valve
    作者: Wu, CF;Herman, BA;Retta, SM;Grossman, LW;Liu, JS;Hwang, NHC
    貢獻者: Division of Medical Engineering Research
    摘要: In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Bjork-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.
    關鍵詞: Engineering, Biomedical
    日期: 2005-06
    關聯: Annals of Biomedical Engineering. 2005 Jun;33(6):743-750.
    Link to: http://dx.doi.org/10.1007/s10439-005-3237-1
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0090-6964&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000230075100003
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=21144455338
    顯示於類別:[黃煥常(2000-2008)] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    000230075100003.pdf193KbAdobe PDF806檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋