    题名: An integrated microfluidic system for cholangiocarcinoma diagnosis from bile by using specific affinity probes
    作者: Lu, TH;Chiang, NJ;Tsai, YC;Gopinathan, P;Huang, CJ;Chang, JL;Tu, HC;Shan, YS;Hung, SC;Lee, GB
    贡献者: National Institute of Cancer Research
    摘要: Cancer can destroy human lives, pose significant financial burdens, and be difficult to diagnose in its early stages. For instance, the conventional antibody-body tests, such as carbohydrate antigen 19-9 (CA19-9) and carci-noembryonic antigen (CEA) which have been routinely used in laboratory tests, are not specific enough for bile duct cholangiocarcinoma (CCA), meaning that it typically remains undiagnosed until advanced stages. Thus, we aim to develop an automated integrated microfluidic system to facilitate the process of CCA diagnosis. In this system, tumor cells were automatically detected in small volume of CCA patient bile (3 mL) via three CCA-specific affinity reagents, including an antibody, an aptamer, and a glycosaminoglycan, which were mobilized on magnetic beads. This integrated microfluidic system automated the entire procedure involved bile centrifu-gation and CCA capture/staining in only 80 min (20, 30, & 30 min for sample treatment, cell capture, & im-munostaining, respectively). Single-blind tests of clinical samples from CCA patients and non-CCA individuals with all three affinity reagents were conducted. Three out of three positive and four out of four negative samples were tested accurately, as determined through use of CCA and non-CCA patient samples. This integrated microfluidic system may therefore serve as a promising tool for improving detection of CCA.
    日期: 2022-12-15
    關聯: Sensors and Actuators B-Chemical. 2022 Dec 15;373:Article number 132724.
    Link to: http://dx.doi.org/10.1016/j.snb.2022.132724
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=0925-4005&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000866468200005
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85138765578
    显示于类别:[姜乃榕] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    ISI000866468200005.pdf6634KbAdobe PDF228检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈