    题名: Usability of wearable devices with a novel cardiac force index for estimating the dynamic cardiac function: Observational study
    作者: Hsiao, PJ;Chiu, CC;Lin, KH;Hu, FK;Tsai, PJ;Wu, CT;Pang, YK;Lin, Y;Kuo, MH;Chen, KH;Wu, YS;Wu, HY;Chang, YT;Chang, YT;Cheng, CS;Chuu, CP;Lin, FH;Chang, CW;Li, YK;Chan, JS;Chu, CM
    贡献者: Institute of Cellular and Systems Medicine
    摘要: BACKGROUND: Long-distance running can be a form of stress to the heart. Technological improvements combined with the public's gradual turn toward mobile health (mHealth), self-health, and exercise effectiveness have resulted in the widespread use of wearable exercise products. The monitoring of dynamic cardiac function changes during running and running performance should be further studied. OBJECTIVE: We investigated the relationship between dynamic cardiac function changes and finish time for 3000-meter runs. Using a wearable device based on a novel cardiac force index (CFI), we explored potential correlations among 3000-meter runners with stronger and weaker cardiac functions during running. METHODS: This study used the American product BioHarness 3.0 (Zephyr Technology Corporation), which can measure basic physiological parameters including heart rate, respiratory rate, temperature, maximum oxygen consumption, and activity. We investigated the correlations among new physiological parameters, including CFI = weight * activity / heart rate, cardiac force ratio (CFR) = CFI of running / CFI of walking, and finish times for 3000-meter runs. RESULTS: The results showed that waist circumference, smoking, and CFI were the significant factors for qualifying in the 3000-meter run. The prediction model was as follows: ln (3000 meters running performance pass probability / fail results probability) = -2.702 - 0.096 × [waist circumference] - 1.827 × [smoke] + 0.020 × [ACi7]. If smoking and the ACi7 were controlled, contestants with a larger waist circumference tended to fail the qualification based on the formula above. If waist circumference and ACi7 were controlled, smokers tended to fail more often than nonsmokers. Finally, we investigated a new calculation method for monitoring cardiac status during exercise that uses the CFI of walking for the runner as a reference to obtain the ratio between the cardiac force of exercise and that of walking (CFR) to provide a standard for determining if the heart is capable of exercise. A relationship is documented between the CFR and the performance of 3000-meter runs in a healthy 22-year-old person. During the running period, data are obtained while participant slowly runs 3000 meters, and the relationship between the CFR and time is plotted. The runner's CFR varies with changes in activity. Since the runner's acceleration increases, the CFR quickly increases to an explosive peak, indicating the runner's explosive power. At this period, the CFI revealed a 3-fold increase (CFR=3) in a strong heart. After a time lapse, the CFR is approximately 2.5 during an endurance period until finishing the 3000-meter run. Similar correlation is found in a runner with a weak heart, with the CFR at the beginning period being 4 and approximately 2.5 thereafter. CONCLUSIONS: In conclusion, the study results suggested that measuring the real-time CFR changes could be used in a prediction model for 3000-meter running performance.
    日期: 2020-07-21
    關聯: JMIR Mhealth Uhealth. 2020 Jul 21;8(7):Article number e15331.
    Link to: http://dx.doi.org/10.2196/15331
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=2291-5222&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000555956500001
    Cited Times(Scopus): https://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85088680850
    显示于类别:[褚志斌] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    PUB32706725.pdf1989KbAdobe PDF309检视/开启


    在NHRI中所有的数据项都受到原著作权保护.

    TAIR相关文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈