Nerve conduction block with a high intensity-focused ultrasound (HIFU) transducer has been performed in normal and diabetic animal models recently. HIFU can reversibly block the conduction of peripheral nerves without damaging the nerves while using an appropriate ultrasonic parameter. Temporary and partial block of the action potentials of nerves shows that HIFU has the potential to be a useful clinical treatment for pain relief. This work demonstrates the procedures for suppressing the action potentials of neuropathic nerves in diabetic rats in vivo using an HIFU transducer. The first step is to generate adult male diabetic neuropathic rats by streptozotocin (STZ) injection. The second step is to evaluate the peripheral diabetic neuropathy in STZ-induced diabetic rats by an electronic von Frey probe and a hot plate. The final step is to record in vivo extracellular action potentials of the nerve exposed to HIFU sonication. The method showed here may benefit the study of ultrasound analgesic applications.
Date:
2017-10-20
Relation: