    題名: Performance evaluation of full facepiece respirators with cartridges
    作者: Lee, SA;Chen, YL;Hwang, DC;Wu, CC;Chen, JK
    貢獻者: Institute of Biomedical Engineering and Nanomedicine
    摘要: Full facepiece respirators (FFRs) with charcoal cartridges are very common wearable devices for industrial or military purposes preventing respiratory tract, face, eyes, and mouth from hazards exposure. However, related research for performance evaluation was rare. We aimed to use a self-developed testing system investigating (1) filtration efficiency (FE) of aerosols in charcoal cartridges; (2) breakthrough time of cyclohexane in charcoal cartridges; (3) fit factors (FFs) and (4) protection factors (PFs) of FRRs. The results showed that FE of charcoal cartridges against 0.3 µm of sodium chloride (NaCl) and dioctyl phthalate (DOP) particles under 85 L min–1 were 99.93% and 99.89%, respectively, which did not meet the standard 99.97% regulated for filters such as P100 and HEPA. As for 42.5 L min–1 condition (dual canisters), the FE against NaCl (99.97%) did meet the requirement set for HEPA (99.97%); however, that against DOP (99.95%) failed to meet the standard. In addition, the breakthrough time of 3000ppm cyclohexane was 31 min under 32 L min–1, which was longer than the 30 min standard described in CNS6636 Z2023 and JIS8152. As to the results of fit test among 21 subjects, only 1 failed to meet the requirement (fit factor = 500) and the average of fit factors was 8342 ± 5892. The mean value of protection factors was 112.3 ± 54.6 while 3 users had lower PFs than the assigned protection factor (APF = 50) regulated by Occupational Safety and Health Administration (OSHA). APFs obtained for particles less than 100 nm were smaller than the APF standard regulated by OSHA, indicating APF standards may be overestimated for such particle size. Therefore, users should be aware of potential risks caused by such substances in nano-sized scale (e.g., nanoparticles or viruses) when wearing FFRs.
    日期: 2017-05
    關聯: Aerosol and Air Quality Research. 2017 May;17(5):1316-1328.
    Link to: http://dx.doi.org/10.4209/aaqr.2016.11.0485
    JIF/Ranking 2023: http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcAuth=NHRI&SrcApp=NHRI_IR&KeyISSN=1680-8584&DestApp=IC2JCR
    Cited Times(WOS): https://www.webofscience.com/wos/woscc/full-record/WOS:000403503700018
    Cited Times(Scopus): http://www.scopus.com/inward/record.url?partnerID=HzOxMe3b&scp=85018448725
    顯示於類別:[陳仁焜] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    SCP85018448725.pdf1604KbAdobe PDF402檢視/開啟


    在NHRI中所有的資料項目都受到原著作權保護.

    TAIR相關文章

    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋